DuraShield® KAPE

Hanita Coatings RCA Ltd
Layers: PVDF / AL / PET / EVA
Region: Israel Israel
Note: Your Enquiry will be sent directly to Hanita Coatings RCA Ltd.

Alternative Product

From $7.50 / m2
  • Layers: Tedlar(PVF) / PET / Tedlar(PVF)
  • Total Thickness: 350±35 µm
  • Tensile Strength (MD): --
  • Thermal Shrinkage (MD):
  • Thermal Shrinkage (TD):
  • Elongation (Length/MD ): --
  • Elongation (Width/TD ): --
  • Interlayer Peel Strength: ≥4 N/cm
  • Peel Strength (EVA-Backsheet): ≥40 N/cm
  • Tensile Strength (Width/TD ): --
  • Partial Discharge Voltage: ≥1010 VDC
  • Breakdown Voltage: 20 kV
  • MVTR: 3 g/m2per day
  • Width:
  • Weight:

Product Characteristics

Product Characteristics  
Outer(Air)Layer PVDF
Outer(Air)Layer Thickness 30 µm
Mid Layer 1 AL
Mid Layer 1 Thickness 17 µm
Mid Layer 2 PET
Mid Layer 2 Thickness 190 µm
Inner(Cell)Layer EVA
Inner(Cell)Layer Thickness 100 µm
Total Thickness 350±17.5 µm
Outer(Air)Layer Colour Black
Inner(Cell)Layer Colour
Stability Characteristics  
Tensile Strength (Length/MD) 60 Mpa
Tensile Strength (Width/TD) 69 Mpa
Elongation (Length/MD) 110 %
Elongation (Width/TD) 90 %
Interlayer Peel Strength ≥4 N/cm
Peel Strength (EVA-Backsheet) ≥70 N/cm
Thermal Shrinkage (Length/MD) ≤1.5 %
Thermal Shrinkage (Width/TD) ≤1.5 %
Moisture Vapour Transmission Rate(MVTR) ≤0.005 g/m2per day
Optical & Thermal Characteristics  
Partial Discharge Voltage ≥1000 VDC