RPS TL-UL System 0917-1283

Bonfiglioli Riduttori S.P.A.
Type: On-grid
Power Range: 917~1283 kW
Region: Italy Italy
Note: Your Enquiry will be sent directly to Bonfiglioli Riduttori S.P.A..

Alternative Product

From $0.150 / Wp
  • TYPE: Off-grid
  • Product Warranty: 2 Years
  • Protection Class: --
  • Dimension: 100x272x355 mm
  • Weight: 6.8 kg
  • Max. DC Power: --
  • Max. DC Voltage: 230 V
  • Max. DC Current: 80 A
  • MPP(T) Voltage Range: 15~80 V
  • No of MPP Trackers: --
  • Max. AC Power: 0.8 kW
  • Frequency: 50,60 Hz
  • Max. Efficiency: 98 %
  • Euro Efficiency: --
  • Feed-in Phases: 1

Product Characteristics

Model No.
RPS TL-UL 0917 RPS TL-UL 1001 RPS TL-UL 1100 RPS TL-UL 1283
Input Data(DC)  
Max. DC Voltage
1000 V 1000 V 1000 V 1000 V
Max. DC Current
1750 A 1900 A 2100 A 2450 A
MPP(T) Voltage Range
500~875 V 500~875 V 500~875 V 500~875 V
No of MPP Trackers
5 6 6 7
Output Data (AC)  
Max. AC Power
917 kW 1000 kW 1100 kW 1283 kW
Output AC Voltage Range
290~363 V 290~363 V 290~363 V 290~363 V
Nominal AC Voltage
330 V 330 V 330 V 330 V
Max. AC Current
1600 A 1750 A 1920 A 2240 A
Frequency
60 Hz 60 Hz 60 Hz 60 Hz
Power Factor (cosθ)
0.99 0.99 0.99 0.99
Distortion (THD)
< 3 % < 3 % < 3 % < 3 %
Max. Efficiency
98.6 % 98.6 % 98.6 % 98.6 %
Euro Efficiency
98.4 % 98.4 % 98.4 % 98.4 %
General Data  
Dimensions (H/W/D) 
2100x3800x800 mm 2100x4400x800 mm 2100x4400x800 mm 2100x5000x800 mm
Weight
3000 kg 3550 kg 3550 kg 4100 kg
Operating Temperature -20 ~ +55 ℃
Transformer Transformerless
Protection Class IP20
Interface RS 485
Protection Features  
Protection Features Anti Island Protection(ENS), Overcurrent Protection, DC Load Disconnector, Ground Fault monitoring, Isolation Monitoring, Grid Monitoring

Bonfiglioli Riduttori S.P.A.

Via Giovanni XXIII, 7/A 40012, Lippo di Calderara di Reno, Bologna
No. Staff: 3114
Send message to this supplier

LinkedIn Profiles

23 More Series From Bonfiglioli Riduttori S.P.A.

  • RPS 450 Compact
    27~150 kW On-grid
  • RPS 450 Compact Outdoor
    27~150 kW On-grid
  • RPS Endurance
    575 kW On-grid
  • Master-Slave-270V
    250~750 kW On-grid
  • Master-Slave-300V
    280~1164 kW On-grid
  • Master-Slave-330V
    367~1283 kW On-grid
  • Master-Slave-360V
    400~1400 kW On-grid
  • Master-Slave- 380V
    421~1474 kW On-grid
  • Master-Slave- 406V
    450~1575 kW On-grid
  • Multi-MPPT- 270V
    250~750 kW On-grid
  • Multi-MPPT- 300V
    280~1164 kW On-grid
  • Multi-MPPT- 330V
    367~1283 kW On-grid
  • Multi-MPPT- 360V
    400~1400 kW On-grid
  • Multi-MPPT- 380V
    421~1474 kW On-grid
  • Multi-MPPT- 406V
    450~1575 kW On-grid
  • RPS TL CN
    500~1263 kW On-grid
  • RPS Station ICON-LV CN
    1000~2000 kW On-grid
  • RPS TL DC Optimizer Variants
    500~1750 kW On-grid
  • RPS TL-UL System 0367-0733
    367~733 kW On-grid
  • RPS TL-UL System 0400-0800
    400~800 kW On-grid
  • RPS TL-UL System 0400-1400
    400~1400 kW On-grid
  • RPS Station NA
    1000~2800 kW On-grid
  • RPS Station ICON-LV
    1053~3150 kW On-grid