Model No.
|
ASW3000-T
|
ASW4000-T
|
ASW5000-T
|
ASW6000-T
|
ASW8000-T
|
ASW10000-T
|
|
Input Data(DC)
|
|
Max. DC Power
|
4.5 kW
|
6 kW
|
7.5 kW
|
9 kW
|
12 kW
|
15 kW
|
|
Max. DC Voltage
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
|
Rated DC Voltage
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
|
Min. DC Voltage to Start Feed In
|
120 V
|
120 V
|
120 V
|
120 V
|
120 V
|
120 V
|
|
Max. DC Current
|
12 A
|
12 A
|
12 A
|
12 A
|
12 A
|
12 A
|
|
MPP(T) Voltage Range
|
125~950 V
|
125~950 V
|
125~950 V
|
125~950 V
|
125~950 V
|
125~950 V
|
|
No of MPP Trackers
|
|
DC Inputs
|
|
Output Data (AC)
|
|
Max. AC Power
|
3 kW
|
4 kW
|
5 kW
|
6 kW
|
8 kW
|
10 kW
|
|
Nominal AC Power
|
3 kW
|
4 kW
|
5 kW
|
6 kW
|
8 kW
|
10 kW
|
|
Output AC Voltage Range
|
180~295 V
|
180~295 V
|
180~295 V
|
180~295 V
|
180~295 V
|
180~295 V
|
|
Nominal AC Voltage
|
220, 230, 240 V
|
220, 230, 240 V
|
220, 230, 240 V
|
220, 230, 240 V
|
220, 230, 240 V
|
220, 230, 240 V
|
|
Rated AC Voltage
|
230 V
|
230 V
|
230 V
|
230 V
|
230 V
|
230 V
|
|
Max. AC Current
|
5 A
|
6.7 A
|
8.4 A
|
9.1 A
|
13.3 A
|
15.2 A
|
|
Frequency Range
|
45-55 Hz
|
45-55 Hz
|
45-55 Hz
|
45-55 Hz
|
45-55 Hz
|
45-55 Hz
|
|
Frequency
|
50 Hz
|
50 Hz
|
50 Hz
|
50 Hz
|
50 Hz
|
50 Hz
|
|
Power Factor (cosθ)
|
|
Distortion (THD)
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
|
No of feed-in phases
|
|
General Data
|
|
Dimensions (H/W/D)
|
375x424x148 mm
|
375x424x148 mm
|
375x424x148 mm
|
375x424x148 mm
|
375x424x148 mm
|
375x424x148 mm
|
|
Weight
|
14.5 kg
|
14.5 kg
|
14.5 kg
|
14.5 kg
|
16 kg
|
16 kg
|
|
Power Consumption at Night
|
< 1 W
|
< W
|
< 1 W
|
< W
|
< 1 W
|
< 1 W
|
|
Noise Level
|
< 35 dB(A)
|
< 35 dB(A)
|
< 35 dB(A)
|
< 35 dB(A)
|
< 45 dB(A)
|
< 45 dB(A)
|
|
Operating Temperature
|
-25 ~ +60 ℃
|
Transformer
|
Transformerless
|
Protection Class
|
IP65
|
Humidity
|
0-100 %
|
Cooling
|
Natural
|
Max. Altitude
|
3000 m
|
Interface
|
RS 485, WLAN
|
Display
|
LED
|
Protection Features
|
|
Protection Features
|
Anti Island Protection(ENS), Short Circuit Protection, Overload Protection, Overvoltage Protection, Overcurrent Protection, Overtemperature Protection, Residual Current Device (RCD), Reverse Polarity Protection, DC Load Disconnector, Ground Fault Monitoring, Isolation Monitoring, Grid Monitoring
|
PDF
|
|
Download Manufacturer's PDF
|
|