Model No.
|
GC-244
|
GC-246
|
GC-248
|
GC-250
|
GC-252
|
GC-254
|
|
Input Data(DC)
|
|
Max. DC Voltage
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
|
Max. DC Current
|
150 A
|
185 A
|
270 A
|
390 A
|
490 A
|
610 A
|
|
MPP(T) Voltage Range
|
450~850 V
|
450~850 V
|
450~850 V
|
450~850 V
|
450~850 V
|
450~850 V
|
|
No of MPP Trackers
|
|
Output Data (AC)
|
|
Max. AC Power
|
60 kW
|
75 kW
|
110 kW
|
160 kW
|
200 kW
|
250 kW
|
|
Output AC Voltage Range
|
304~498 V
|
304~498 V
|
304~498 V
|
304~498 V
|
304~498 V
|
304~498 V
|
|
Nominal AC Voltage
|
380, 400, 415 V
|
380, 400, 415 V
|
380, 400, 415 V
|
380, 400, 415 V
|
380, 400, 415 V
|
380, 400, 415 V
|
|
Max. AC Current
|
87 A
|
108 A
|
160 A
|
230 A
|
290 A
|
360 A
|
|
Frequency Range
|
49.5-60.5 Hz
|
49.5-60.5 Hz
|
49.5-60.5 Hz
|
49.5-60.5 Hz
|
49.5-60.5 Hz
|
49.5-60.5 Hz
|
|
Frequency
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
|
Power Factor (cosθ)
|
0.99
|
0.99
|
0.99
|
0.99
|
0.99
|
0.99
|
|
Distortion (THD)
|
< 2 %
|
< 2 %
|
< 2 %
|
< 2 %
|
< 2 %
|
< 2 %
|
|
No of feed-in phases
|
|
Max. Efficiency
|
98 %
|
98 %
|
98 %
|
98 %
|
98 %
|
98 %
|
|
Euro Efficiency
|
95 %
|
95 %
|
95 %
|
95 %
|
95 %
|
95 %
|
|
General Data
|
|
Dimensions (H/W/D)
|
1700x800x800 mm
|
1700x800x800 mm
|
1900x1200x1100 mm
|
1900x1200x1100 mm
|
1900x1400x1100 mm
|
1900x1400x1100 mm
|
|
Weight
|
400 kg
|
440 kg
|
700 kg
|
900 kg
|
1500 kg
|
1700 kg
|
|
Power Consumption at Night
|
< 40 W
|
< 40 W
|
< 40 W
|
< 40 W
|
< 40 W
|
< 40 W
|
|
Noise Level
|
< 50 dB(A)
|
< 50 dB(A)
|
< 50 dB(A)
|
< 50 dB(A)
|
< 50 dB(A)
|
< 50 dB(A)
|
|
Operating Temperature
|
-10 ~ +50 ℃
|
Protection Class
|
IP20
|
Humidity
|
0-95 %
|
Cooling
|
Fan
|
Interface
|
RS 232, RS 485
|
Display
|
LED
|
Protection Features
|
|
Protection Features
|
Overvoltage Protection, Ground Fault Monitoring
|
PDF
|
|