Model No.
|
F3000
|
F3600
|
F4600
|
F5000
|
F5300
|
F6000
|
|
Input Data(DC)
|
|
Max. DC Power
|
4.5 kW
|
5.4 kW
|
6.9 kW
|
7.5 kW
|
7.95 kW
|
9 kW
|
|
Max. DC Voltage
|
600 V
|
600 V
|
600 V
|
600 V
|
600 V
|
600 V
|
|
Rated DC Voltage
|
360 V
|
360 V
|
360 V
|
360 V
|
360 V
|
360 V
|
|
Min. DC Voltage to Start Feed In
|
120 V
|
120 V
|
120 V
|
120 V
|
120 V
|
120 V
|
|
Max. DC Current
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
|
MPP(T) Voltage Range
|
80~550 V
|
80~550 V
|
80~550 V
|
80~550 V
|
80~550 V
|
80~550 V
|
|
No of MPP Trackers
|
|
DC Inputs
|
|
Output Data (AC)
|
|
Max. AC Power
|
3.3 kW
|
3.96 kW
|
5.06 kW
|
5.5 kW
|
5.83 kW
|
6 kW
|
|
Max. AC Current
|
14.3 A
|
17.2 A
|
22 A
|
23.9 A
|
25.3 A
|
26.1 A
|
|
Frequency
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
|
Power Factor (cosθ)
|
|
Distortion (THD)
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
|
No of feed-in phases
|
|
Max. Efficiency
|
97.4 %
|
97.4 %
|
97.4 %
|
97.4 %
|
97.4 %
|
97.4 %
|
|
Euro Efficiency
|
96.8 %
|
96.8 %
|
96.8 %
|
96.8 %
|
96.8 %
|
96.8 %
|
|
General Data
|
|
Dimensions (H/W/D)
|
476.5x402x148 mm
|
476.5x402x148 mm
|
476.5x402x148 mm
|
476.5x402x148 mm
|
476.5x402x148 mm
|
476.5x402x148 mm
|
|
Weight
|
15.5 kg
|
15.5 kg
|
15.5 kg
|
15.5 kg
|
15.5 kg
|
15.5 kg
|
|
Power Consumption at Night
|
< 1 W
|
< 1 W
|
< 1 W
|
< 1 W
|
< 1 W
|
< 1 W
|
|
Noise Level
|
< 30 dB(A)
|
< 30 dB(A)
|
< 30 dB(A)
|
< 30 dB(A)
|
< 30 dB(A)
|
< 30 dB(A)
|
|
Operating Temperature
|
-20 ~ +60 ℃
|
Transformer
|
Transformerless
|
Protection Class
|
IP65
|
Humidity
|
0-100 %
|
Cooling
|
Natural
|
Max. Altitude
|
3000 m
|
Interface
|
RS 485, WLAN
|
Display
|
LCD
|
Protection Features
|
|
Protection Features
|
Anti Island Protection(ENS), Short Circuit Protection, Overvoltage Protection, Overcurrent Protection, Overtemperature Protection, Residual Current Device (RCD), Reverse Polarity Protection, Surge Protection, Isolation Monitoring
|
PDF
|
|
Download Manufacturer's PDF
|
|