Model No.
|
EPL3000TL
|
EPL4000KTL
|
EPL5000TL
|
EPL6000TL
|
EPL8000TL
|
EPL10KTL
|
|
Warranty
|
|
Product Warranty (Min)
|
5 Years
|
5 Years
|
5 Years
|
5 Years
|
5 Years
|
5 Years
|
|
Input Data(DC)
|
|
Max. DC Power
|
4.5 kW
|
6 kW
|
7.5 kW
|
9 kW
|
12 kW
|
14 kW
|
|
Max. DC Voltage
|
500 V
|
500 V
|
500 V
|
500 V
|
500 V
|
500 V
|
|
Rated DC Voltage
|
360 V
|
360 V
|
360 V
|
360 V
|
360 V
|
360 V
|
|
Min. DC Voltage to Start Feed In
|
100 V
|
100 V
|
100 V
|
100 V
|
100 V
|
100 V
|
|
Max. DC Current
|
26 A
|
26 A
|
26 A
|
52 A
|
52 A
|
52 A
|
|
MPP(T) Voltage Range
|
100~450 V
|
100~450 V
|
100~450 V
|
100~450 V
|
100~450 V
|
100~450 V
|
|
No of MPP Trackers
|
|
DC Inputs
|
|
Connectors
|
|
Output Data (AC)
|
|
Max. AC Power
|
3.3 kW
|
4.4 kW
|
5.5 kW
|
6.6 kW
|
8.8 kW
|
10.5 kW
|
|
Nominal AC Power
|
3 kW
|
4 kW
|
5 kW
|
6 kW
|
8 kW
|
10 kW
|
|
Output AC Voltage Range
|
220~230 V
|
220~230 V
|
220~230 V
|
220~230 V
|
220~230 V
|
220~230 V
|
|
Max. AC Current
|
15 A
|
20 A
|
25 A
|
28.8 A
|
38.5 A
|
45.6 A
|
|
Frequency
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
|
Power Factor (cosθ)
|
|
Distortion (THD)
|
< 0.5 %
|
< 0.5 %
|
< 0.5 %
|
< 0.5 %
|
< 0.5 %
|
< 0.5 %
|
|
No of feed-in phases
|
|
Max. Efficiency
|
97.6 %
|
97.6 %
|
97.6 %
|
97.8 %
|
97.8 %
|
97.8 %
|
|
Euro Efficiency
|
96.5 %
|
96.5 %
|
96.5 %
|
96.6 %
|
96.6 %
|
96.6 %
|
|
General Data
|
|
Dimensions (H/W/D)
|
210x500x55 mm
|
210x500x55 mm
|
210x500x55 mm
|
210x500x55 mm
|
210x500x55 mm
|
210x500x55 mm
|
|
Weight
|
25 kg
|
25 kg
|
25 kg
|
25 kg
|
25 kg
|
25 kg
|
|
Noise Level
|
< 30 dB(A)
|
< 30 dB(A)
|
< 30 dB(A)
|
< 30 dB(A)
|
< 30 dB(A)
|
< 30 dB(A)
|
|
Operating Temperature
|
-40 ~ +60 ℃
|
Transformer
|
Transformerless
|
Protection Class
|
IP65
|
Cooling
|
Fan
|
Interface
|
RS 485, WLAN
|
Display
|
LCD
|
Protection Features
|
|
Protection Features
|
Anti Island Protection(ENS), Short Circuit Protection, Overload Protection, Overvoltage Protection, Overcurrent Protection, Overtemperature Protection, Residual Current Device (RCD), Reverse Polarity Protection, Surge Protection, Ground Fault Monitoring, Isolation Monitoring
|