Model No.
|
ACEY-R10KH3
|
ACEY-R12KH3
|
ACEY-R15KH3
|
ACEY-R6KH3
|
ACEY-R8KH3
|
|
Warranty
|
|
Product Warranty (Min)
|
5 Years
|
5 Years
|
5 Years
|
5 Years
|
5 Years
|
|
Input Data(DC)
|
|
Max. DC Power
|
15 kW
|
18 kW
|
22.5 kW
|
9 kW
|
12 kW
|
|
Max. DC Voltage
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
|
Rated DC Voltage
|
600 V
|
600 V
|
600 V
|
600 V
|
600 V
|
|
Min. DC Voltage to Start Feed In
|
125 V
|
125 V
|
125 V
|
125 V
|
125 V
|
|
Max. DC Current
|
|
MPP(T) Voltage Range
|
250~850 V
|
250~850 V
|
250~850 V
|
250~850 V
|
250~850 V
|
|
No of MPP Trackers
|
|
Output Data (AC)
|
|
Max. AC Power
|
11 kW
|
13.2 kW
|
16.5 kW
|
66 kW
|
88 kW
|
|
Nominal AC Power
|
10 kW
|
12 kW
|
15 kW
|
6 kW
|
8 kW
|
|
Nominal AC Voltage
|
380, 400 V
|
380, 400 V
|
380, 400 V
|
380, 400 V
|
380, 400 V
|
|
Max. AC Current
|
31.8 A
|
38.2 A
|
47.6 A
|
19.1 A
|
25.5 A
|
|
Distortion (THD)
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
|
No of feed-in phases
|
|
Max. Efficiency
|
98.2 %
|
98.2 %
|
97.6 %
|
97.9 %
|
97.9 %
|
|
General Data
|
|
Dimensions (H/W/D)
|
596x566x220 mm
|
596x566x220 mm
|
596x566x220 mm
|
596x566x220 mm
|
596x566x220 mm
|
|
Weight
|
31 kg
|
32 kg
|
34 kg
|
30 kg
|
30 kg
|
|
Power Consumption at Night
|
< 3 W
|
< 3 W
|
< 3 W
|
< 3 W
|
< 3 W
|
|
Noise Level
|
< 25 dB(A)
|
< 25 dB(A)
|
< 25 dB(A)
|
< 25 dB(A)
|
< 25 dB(A)
|
|
Operating Temperature
|
-25 ~ +60 ℃
|
Transformer
|
High Frequency-Transformer
|
Protection Class
|
IP65
|
Humidity
|
0-100 %
|
Cooling
|
Natural
|
Max. Altitude
|
4000 m
|
Interface
|
RS 485
|
Display
|
LCD
|
Protection Features
|
|
Protection Features
|
Anti Island Protection(ENS), Short Circuit Protection, Overload Protection, Overvoltage Protection, Overcurrent Protection, Overtemperature Protection, Residual Current Device (RCD), Reverse Polarity Protection, Surge Protection, DC Load Disconnector, Ground Fault Monitoring, Isolation Monitoring, Grid Monitoring
|
PDF
|
|
Download Manufacturer's PDF
|
|